M-003 Dual Channel Parallel Injection - Cycle Composer

From LEAP

(Difference between revisions)
Jump to: navigation, search
Line 47: Line 47:
|}
|}
<br>
<br>
-
== For other cost/time saving measures consider:===
+
=== For other cost/time saving measures consider:===
* LEAP offers multiple choices of Valve Self Wash Stations to aid in cleaning the valve [http://www.leapwiki.com/mediawiki/index.php?title=Valve_Washing]
* LEAP offers multiple choices of Valve Self Wash Stations to aid in cleaning the valve [http://www.leapwiki.com/mediawiki/index.php?title=Valve_Washing]
* Dual Channel Serial Injection (M-001) using Analyst and ICC-CE [http://www.leapwiki.com/mediawiki/index.php?title=M-001_Dual_Channel_Serial_Injection_-_Analyst_with_ICC-CE]
* Dual Channel Serial Injection (M-001) using Analyst and ICC-CE [http://www.leapwiki.com/mediawiki/index.php?title=M-001_Dual_Channel_Serial_Injection_-_Analyst_with_ICC-CE]

Revision as of 23:17, 28 April 2009

LC Dual Stream Staggered Injections
Application Type
  SPECIAL
Application ID
  M-003
Description
  High Throughput LC injections alternating onto two analytical columns.
www.leaptec.comwww.leapwiki.com
www.leaptec.com
www.leapwiki.com

Contents

Overview

This configuration allows shorter cycle times by limiting the acquisition time to just the peaks of interest and regenerating the alternating column during the acquisition. It uses Cycle Composer Software[1] - this application is run with Standard LEAP macros outside of Analyst® Software[2] from Applied Biosystems Inc®

If the peaks of interest come off together in the middle of the gradient (as shown below) then it is possible to utilize the front cut and back cut time to increase throughput.

Image:Front-backcut.png

If injections are staggered in the following way, there is a potential for up to 100% gain:


Image:Timeline_Dual_Stream_1.png


Hardware Requirements

  • TrioVS multiple valve system is required in addition to the standard injection valve.


Image:Valve_Drawing_Dual_Stream_1.png

Code Application Control SW Key Hardware Key Benefits Restrictions GLP
M-003 Dual Channel Parallel Injection

Provides shorter cycle times by limiting the acquisition time to just the peaks of interest and regenerating columns during acquisition
Cycle Composer outside of Analyst * Trio VS
*6 port injection valve
*FWS in front of 6 port valve
* Gradient Pump
* Regeneration pump
* Saving of Front and Back Cut
* Provides "Look Ahead"
*Provides staggering of injections
* Requires matching sample lists in Cycle Composer and Analyst
* Columns may perform slightly differently on alternating samples
No


For other cost/time saving measures consider:

  • LEAP offers multiple choices of Valve Self Wash Stations to aid in cleaning the valve [3]
  • Dual Channel Serial Injection (M-001) using Analyst and ICC-CE [4]
  • Dual Channel Serial Injection with Front Cut (M-002) using Analyst and ICC-CE [5]
  • “Look Ahead”, sample prep before injection (M-004) using LEAP Shell Software [6]
  • Dual Channel Parallel Injection (M-005) using LEAP Shell software [7]
  • LEAP Shell Software and application for custom injections and scheduling [8]

www.leaptec.comwww.leapwiki.com
www.leaptec.com
www.leapwiki.com

Contact LEAP

For additional information about this technique please contact LEAP Technologies for detailed information