| style="border:1px solid blue;"|'''Dual Channel Parallel Injection'''<br><br>Provides shorter cycle times by limiting the acquisition time to just the peaks of interest and regenerating columns during acquisition
| style="border:1px solid blue;"|'''Dual Channel Parallel Injection'''<br><br>Provides shorter cycle times by limiting the acquisition time to just the peaks of interest and regenerating columns during acquisition
| style="border:1px solid blue;"|Cycle Composer outside of Analyst
| style="border:1px solid blue;"|Cycle Composer outside of Analyst
-
| style="border:1px solid blue;"|* Trio VS<br>*6 port injection valve<br>*FWS in front of 6 port valve* Gradient Pump<br>* Regeneration pump
+
| style="border:1px solid blue;"|* Trio VS<br>*6 port injection valve<br>*FWS in front of 6 port valve<br>* Gradient Pump<br>* Regeneration pump
-
| style="border:1px solid blue;"|* Saving of Front and Back Cut<br>* Provides "Look Ahead"<br> *Provids staggering of injections
+
| style="border:1px solid blue;"|* Saving of Front and Back Cut<br>* Provides "Look Ahead"<br> *Provides staggering of injections
| style="border:1px solid blue;"|* Requires matching sample lists in Cycle Composer and Analyst<br>* Columns may perform slightly differently on alternating samples
| style="border:1px solid blue;"|* Requires matching sample lists in Cycle Composer and Analyst<br>* Columns may perform slightly differently on alternating samples
-
| style="border:1px solid blue;"|Yes
+
| style="border:1px solid blue;"|No
|}
|}

Revision as of 23:11, 28 April 2009

Testing of Wiki page location
Application Type
  WIKI TEST
Application ID
  ABC
Description
  Wiki Testing Page for LEAP


Code Application Control SW Key Hardware Key Benefits Restrictions GLP
M-001 Dual Channel Serial Injection

Provides shorter cycle times by regenerating columns during next analytical run
Analyst with ICC-CE * 6 port injection valve
* 10 port Valve
* Gradient Pump
* Regeneration pump
* Saving of regeneration time(Back Cut)
* Increase throughput at little cost
* Control is all within Analyst
* Compliance is not affected
* Can not do "Look Ahead"
* Injections are not staggered
* Peaks of interest must come of early
* Columns may perform slightly differently on alternating samples
Yes
Code Application Control SW Key Hardware Key Benefits Restrictions GLP
M-002 Dual Channel Serial Injection with Front Cut

Provides shorter cycle times by regenerating columns during next analytical run and diverts the solvent front to waste
Analyst with ICC-CE * Trio VS
* Gradient Pump
* Regeneration pump
* Saving of regeneration time(Back Cut)
* Increase throughput at little cost
* Control is all within Analyst
* Compliance is not affected
* Avoids contaminating MS inlet with early eluting compounds and solvent
* Can not do "Look Ahead"
* Injections are not staggered
* Peaks of interest must come of early
* Columns may perform slightly differently on alternating samples
Yes
Code Application Control SW Key Hardware Key Benefits Restrictions GLP
M-003 Dual Channel Parallel Injection

Provides shorter cycle times by limiting the acquisition time to just the peaks of interest and regenerating columns during acquisition
Cycle Composer outside of Analyst * Trio VS
*6 port injection valve
*FWS in front of 6 port valve
* Gradient Pump
* Regeneration pump
* Saving of Front and Back Cut
* Provides "Look Ahead"
*Provides staggering of injections
* Requires matching sample lists in Cycle Composer and Analyst
* Columns may perform slightly differently on alternating samples
No