Sandbox

From LEAP

(Difference between revisions)
Jump to: navigation, search
Line 20: Line 20:
|- align=left
|- align=left
| style="border:1px solid blue;"|'''M-001'''
| style="border:1px solid blue;"|'''M-001'''
-
| style="border:1px solid blue;"|'''Column switching with parallel regeneration'''<br><br>Provides shorter cycle times by regenerating columns during next analytical run
+
| style="border:1px solid blue;"|'''Dual Channel Serial Injection'''<br><br>Provides shorter cycle times by regenerating columns during next analytical run
| style="border:1px solid blue;"|Analyst with ICC-CE  
| style="border:1px solid blue;"|Analyst with ICC-CE  
| style="border:1px solid blue;"|* 6 port injection valve<BR>* 10 port Valve <br>* Gradient Pump<br>* Regeneration pump
| style="border:1px solid blue;"|* 6 port injection valve<BR>* 10 port Valve <br>* Gradient Pump<br>* Regeneration pump

Revision as of 21:28, 28 April 2009

Testing of Wiki page location
Application Type
  WIKI TEST
Application ID
  ABC
Description
  Wiki Testing Page for LEAP


Code Application Control SW Key Hardware Key Benefits Restrictions GLP
M-001 Dual Channel Serial Injection

Provides shorter cycle times by regenerating columns during next analytical run
Analyst with ICC-CE * 6 port injection valve
* 10 port Valve
* Gradient Pump
* Regeneration pump
* Saving of regeneration time(Back Cut)
* Increase throughput at little cost
* Control is all within Analyst
* Compliance is not affected
* Can not do "Look Ahead"
* Injections are not staggered
* Peaks of interest must come of early
* Columns may perform slightly differently on alternating samples
Yes
Code Application Control SW Key Hardware Key Benefits Restrictions GLP
M-002 Dual Channel Serial Injection with Front Cut

Provides shorter cycle times by regenerating columns during next analytical run and diverts the solvent front to waste
Analyst with ICC-CE * Trio VS* Gradient Pump
* Regeneration pump
* Saving of regeneration time(Back Cut)
* Increase throughput at little cost
* Control is all within Analyst
* Compliance is not affected
* Avoids contaminating MS inlet with early eluting compounds and colvent
* Can not do "Look Ahead"
* Injections are not staggered
* Peaks of interest must come of early
* Columns may perform slightly differently on alternating samples
Yes




www.leaptec.comwww.leapwiki.com
www.leaptec.com
www.leapwiki.com

Contact LEAP

For additional information about this technique please contact LEAP Technologies for detailed information