| style="border:1px solid blue;"|'''M-001'''
 +
| style="border:1px solid blue;"|'''Column switching with parallel regeneration'''<br><br>Provides shorter cycle times by regenerating columns during next analytical run
 +
| style="border:1px solid blue;"|Analyst with ICC-CE
 +
| style="border:1px solid blue;"|* 6 port injection valve<BR>* 10 port Valve <br>* Gradient Pump<br>* Regeneration pump
 +
| style="border:1px solid blue;"|* Saving of regeneration time(Back Cut)<br>* Increase throughput at little cost<br> * Control is all within Analyst<br>* Compliance is not affected
 +
| style="border:1px solid blue;"|* Can not do "Look Ahead"<br>* Injections are not staggered<br>* Peaks of interest must come of early<br>* Columns may perform slightly differently on alternating samples
 +
| style="border:1px solid blue;"|Yes
 +
|}
{| cellpadding="6" style="border:1px solid darkgray;"
{| cellpadding="6" style="border:1px solid darkgray;"

Revision as of 21:15, 28 April 2009

Testing of Wiki page location
Application Type
  WIKI TEST
Application ID
  ABC
Description
  Wiki Testing Page for LEAP


Code Application Control SW Key Hardware Key Benefits Restrictions GLP
M-001 Column switching with parallel regeneration

Provides shorter cycle times by regenerating columns during next analytical run
Analyst with ICC-CE * 6 port injection valve
* 10 port Valve
* Gradient Pump
* Regeneration pump
* Saving of regeneration time(Back Cut)
* Increase throughput at little cost
* Control is all within Analyst
* Compliance is not affected
* Can not do "Look Ahead"
* Injections are not staggered
* Peaks of interest must come of early
* Columns may perform slightly differently on alternating samples
Yes
Code Application Control SW Key Hardware Key Benefits Restrictions GLP
M-001 Column switching with parallel regeneration

Provides shorter cycle times by regenerating columns during next analytical run
Analyst with ICC-CE * 6 port injection valve
* 10 port Valve
* Gradient Pump
* Regeneration pump
* Saving of regeneration time(Back Cut)
* Increase throughput at little cost
* Control is all within Analyst
* Compliance is not affected
* Can not do "Look Ahead"
* Injections are not staggered
* Peaks of interest must come of early
* Columns may perform slightly differently on alternating samples
Yes