Sandbox

From LEAP

(Difference between revisions)
Jump to: navigation, search
Line 20: Line 20:
{| cellpadding="6" style="border:1px solid darkgray;"
{| cellpadding="6" style="border:1px solid darkgray;"
-
!width="140"|Left
 
-
!width="150"|Middle
 
-
!width="130"|Right
 
-
!width="200"|Right
 
-
!width="100"|Right
 
|- align=left
|- align=left
-
| style="border:1px solid blue;"|
+
!width="100"|Code
-
[[Image:LEAP Logo.png|120px]]
+
!width="200"|Application
-
| style="border:1px solid #777777;"|
+
!width="120"|Control SW
-
[[Image:LEAP Logo.png|120px|Caption when mouse-over image]]
+
!width="200"|Key Hardware
-
| style="border:1px solid #22AA55;"|<!--greenish border-->
+
!width="100"|Key Benefits
-
[[Image:LEAP Logo.png|120px|Green stellar icon]]
+
!width="100"|Restrictions
-
| style="border:1px solid #22AA55;"|<!--greenish border-->
+
!width="100"|GLP
-
[[Image:LEAP Logo.png|120px|Green stellar icon]]
+
|- align=left
-
| style="border:1px solid #22AA55;"|<!--greenish border-->
+
| style="border:1px solid blue;"|M-001
-
[[Image:LEAP Logo.png|120px|Green stellar icon]]
+
| style="border:1px solid blue;"|Column switching with parallel regeneration <br>Provides shorter cycle times by regenerating columns during next analytical run
-
|- align=center
+
| style="border:1px solid blue;"|Analyst with ICC-CE
-
|Bronze star || Gold star || Green star
+
| style="border:1px solid blue;"|6 port injection valve<BR>10 port Valve <br>Gradient Pump and Regeneration pump
 +
| style="border:1px solid blue;"|Saving of regeneration time(Back Cut)<br> Increase throughput at little cost<br> Control is all within Analyst<br> Compliance is not affected
 +
| style="border:1px solid blue;"|Can not do "Look Ahead"<br> Injections are not staggered<br> Peaks of interest must come of early<br>Columns may perform slightly differently on alternating samples
 +
| style="border:1px solid blue;"|Yes
|}
|}

Revision as of 20:51, 28 April 2009

Testing of Wiki page location
Application Type
  WIKI TEST
Application ID
  ABC
Description
  Wiki Testing Page for LEAP


Quick Overview
Code Application Control SW Key Hardware Key Benefits Restrictions GLP
M-001 Column switching with parallel regeneration
Provides shorter cycle times by regenerating columns during next analytical run
Analyst with ICC-CE PAL
6 port injection valve
10 port Valve
Gradient Pump and Regeneration pump
Saving of regeneration time(Back Cut)
Increase throughput at little cost
Control is all within Analyst
Compliance is not affected
Can not do "Look Ahead"
Injections are not staggered
Peaks of interest must come of early
Columns may perform slightly differently on alternating samples
Yes


Code Application Control SW Key Hardware Key Benefits Restrictions GLP
M-001 Column switching with parallel regeneration
Provides shorter cycle times by regenerating columns during next analytical run
Analyst with ICC-CE 6 port injection valve
10 port Valve
Gradient Pump and Regeneration pump
Saving of regeneration time(Back Cut)
Increase throughput at little cost
Control is all within Analyst
Compliance is not affected
Can not do "Look Ahead"
Injections are not staggered
Peaks of interest must come of early
Columns may perform slightly differently on alternating samples
Yes



www.leaptec.comwww.leapwiki.com
www.leaptec.com
www.leapwiki.com

Contact LEAP

For additional information about this technique please contact LEAP Technologies for detailed information