In-Line Sample Concentration or Filtration
Application Type
  SPECIAL
Application ID
  M-006 & M-007
Description
  In-Line Sample Cleanup


Code Application Control SW Key Hardware Key Benefits Restrictions GLP
M-006 Inline Sample Concentration

SPE Column regenerated during analytical extraction
Analyst with ICC-CE * TrioVS
* Automated concentration and elution of sample on SPE column prior to separation on analytical column * No "Look Ahead"
* Can not prep samples ahead of analytical run
No


Code Application Control SW Key Hardware Key Benefits Restrictions GLP
M-007 Inline Sample Filtration

SPE Column regenerated during analytical extraction
Analyst with ICC-CE * TrioVS
* Automated filtration of sample on cleanup column prior to separation on analytical column * No "Look Ahead"
* Can not prep samples ahead of analytical run
No



On-Line SPE Application Note from ABI for Pesticides in Drinking Water[1]



Contents

Overview

This configuration allows the automated on-line Solid Phase Extraction (SPE). This is run directly from within Analyst Software[2] from Applied Biosystems Inc using a Standard LEAP Cycle (requires ICC-CE software) [3].

There are 2 pumps needed, one for the gradient run and another (higher flow rate and isocratic) for regeneration [4]. This configuration requires a TrioVS Valve [5]. All of the valves must be controlled by the Standard LEAP cycle.
LEAP can not control the MS Selector valve as part of the cycle.

TrioVS valve is used. Flow path intentionally left incomplete. Contact LEAP for more information

Useful links

www.appliedbiosystems.com Application Note [6]


Image:HTC_with_TRIO.png


For other cost/time saving measures consider:

  • LEAP offers multiple choices of Valve Self Wash Stations to aid in cleaning the valve [7]
  • Summary of LC Multi Valve Applications [8]
  • LEAP Shell Software and application for custom injections and scheduling [9]

Contact LEAP

For detailed information on In-line Sample Concentration or Filtration please contact LEAP Technologies