M-002 Dual Channel Serial Injection with front cut - Analyst with ICC-CE
From LEAP
Line 8: | Line 8: | ||
=== Overview === | === Overview === | ||
- | This configuration allows the | + | This configuration allows the front cut of one of the analytical columns while the other one is engaged - giving greater efficiency and higher throughput. This is run directly from within '''Analyst''' using a Custom LEAP Cycle (requires ICC-CE software). |
- | There are 2 pumps needed, one for the gradient run and another (higher flow rate and isocratic) for regeneration. This configuration requires a 6 port valve for sample loading and a 10 port valve for column switching.<br> | + | There are 2 pumps needed, one for the gradient run and another (higher flow rate and isocratic) for regeneration. This configuration requires a 6 port valve for sample loading and a 10 port valve for column switching.<br> All three valves must be controlled by the custom cycle. LEAP can not control the MS Selector valve as part of the cycle. |
+ | |||
+ | |||
+ | [[Image:key_Benefits2.png]] | ||
+ | |||
+ | |||
+ | |||
+ | [[Image:Restrictions.png]] | ||
+ | |||
+ | |||
+ | [[Image:Table M-001.png]] | ||
+ | |||
+ | |||
+ | === Power Point of Regeneration === | ||
+ | *[[:Image:Column_Regeneration.pps| Valve Power Point]] | ||
Line 17: | Line 31: | ||
* [http://www.leaptec.com/ LEAP Technologies, Inc.] | * [http://www.leaptec.com/ LEAP Technologies, Inc.] | ||
- | Keyword: Analyst Software, ICC-CE, PAL,TRIO | + | Keyword: Analyst Software, ICC-CE, PAL, TRIO Valve, 10 port valve, selector valve, injector valve, gradient pump, regeneration pump,back cut, peaks of interest, GLP |
Revision as of 18:41, 25 March 2009
Overview
This configuration allows the front cut of one of the analytical columns while the other one is engaged - giving greater efficiency and higher throughput. This is run directly from within Analyst using a Custom LEAP Cycle (requires ICC-CE software).
There are 2 pumps needed, one for the gradient run and another (higher flow rate and isocratic) for regeneration. This configuration requires a 6 port valve for sample loading and a 10 port valve for column switching.
All three valves must be controlled by the custom cycle. LEAP can not control the MS Selector valve as part of the cycle.
Power Point of Regeneration
Contact LEAP
Keyword: Analyst Software, ICC-CE, PAL, TRIO Valve, 10 port valve, selector valve, injector valve, gradient pump, regeneration pump,back cut, peaks of interest, GLP